Which modification codes apply, what your registration authority is likely to ask, how the Australian Consumer Law protects you, and the documentation to keep. Written for Australian fleet, workshop and compliance staff — not adapted from an overseas market.

Short answer

What applies in Australia when fitting one of these units?

Vehicle modifications are assessed under VSB 14 for light vehicles up to 4.5 tonnes GVM and VSB 6 for heavy vehicles above it, administered by your state or territory registration authority. Whether your specific installation requires approval or examiner sign-off is their decision, not ours. Because the unit generates gas on demand and stores none, there is no pressurised hydrogen inventory to assess. Our goods carry statutory guarantees under the Australian Consumer Law that cannot be excluded, and our written warranty sits in addition to them.

  • VSB 14 — light vehicles up to 4.5 t GVM; VSB 6 — heavy vehicles above
  • Approval pathway is set by your state or territory authority
  • No hydrogen storage on the vehicle — gas is made and consumed on demand
  • Installation is reversible and adds nothing to the fuel system
  • ACL statutory guarantees apply and cannot be contracted out
  • We supply hardware and remote support only — no installer network
Light vehicle code
VSB 14
Heavy vehicle code
VSB 6
Gas storage
None
Statutory rights
ACL — cannot be excluded
Framework

What sits over an installation here.

VSB 14

National Code of Practice for Light Vehicle Construction and Modification

Light vehicles up to 4.5 tonnes GVM

The reference framework state and territory authorities use to assess light-vehicle modifications. Relevant sections cover engine bay additions, electrical installation and secure mounting of components.

VSB 6

National Code of Practice for Heavy Vehicle Modifications

Heavy vehicles above 4.5 tonnes GVM

The equivalent framework for trucks, prime movers and heavy plant on road. Modifications in this class are commonly assessed by an Approved Vehicle Examiner in your state.

State registration authority

Transport for NSW, VicRoads, TMR, DoT WA, and equivalents

Registration and roadworthy administration

Adoption of the national codes and the local approval pathway differ by jurisdiction. Confirm the requirement with your own authority before a fleet-wide rollout.

Australian Consumer Law

Competition and Consumer Act 2010, Schedule 2

Consumer guarantees and claim substantiation

Governs your statutory guarantees on the goods, and requires that any performance claim we make be substantiated before it is made. This is why no headline savings percentage is advertised anywhere on this site.

Workplace health & safety

Model WHS laws as adopted in your jurisdiction

Depot and workshop operations

Fitting and servicing occurs in your workplace under your own safety management system. Because the unit uses deionised water and stores no gas, no caustic chemical or pressurised hydrogen enters that system.

This page is general information, not legal, engineering or compliance advice. Requirements differ between jurisdictions and change over time. Confirm the position for your vehicles with your state or territory authority and a qualified examiner before a fleet rollout.

Warranty

Two warranties, and how they interact.

Your statutory guarantees

Under the Australian Consumer Law our goods come with guarantees that cannot be excluded. You are entitled to a replacement or refund for a major failure, to compensation for any other reasonably foreseeable loss, and to repair or replacement where goods are not of acceptable quality.

Our written warranty

The published product warranty covers the unit itself and is in addition to your statutory rights, never a replacement for them. Terms, duration and exclusions are set out on the warranty page.

Your vehicle manufacturer

A separate relationship we are not party to. Ask them in writing before fitting. They cannot void your statutory guarantees simply because an accessory is present, but they can decline a claim for a fault the accessory caused — which is why documentation matters.

Full terms: Warranty · Returns · Terms

Safety

The points an examiner or safety officer asks about.

No stored gas

Hydrogen and oxygen are generated only while the engine runs and are drawn straight into the intake. There is no cylinder, no accumulator and no residual inventory when the engine is off.

No caustic chemicals

The PEM stack runs on deionised water. No potassium hydroxide or other caustic electrolyte is carried, handled or disposed of, so nothing of that kind enters your WHS chemical register.

Electrical isolation and fusing

The unit draws from the existing 12 V or 24 V supply through its own fused, ignition-switched circuit so it cannot operate with the engine stopped. Wiring and fusing detail is in the installation guide.

Gas line integrity

A bubbler and non-return valve sit between the cell and the intake. The line is small-bore, routed clear of heat and moving parts, and secured — the same discipline as any under-bonnet line.

Secure mounting

The unit must be mounted so it cannot move under vibration, braking or impact loads, which is the point examiners assess most often under the VSB codes.

Full reversibility

Nothing is added to the fuel system and no engine internals are altered, so the vehicle can be returned to its original configuration. That materially simplifies both compliance and resale conversations.

We make no emissions-compliance or certification claim. Fitting a unit does not alter a vehicle's certified emissions status and is not a remedy for an existing defect notice.

Records

Documentation checklist.

  1. 01

    Invoice, model and serial number for each unit

  2. 02

    Installation date, vehicle identification, odometer or hour-meter reading

  3. 03

    Photographs of mounting, wiring, fusing and gas-line connection

  4. 04

    Baseline consumption record taken before fitting

  5. 05

    Written correspondence with the vehicle or engine manufacturer about warranty

  6. 06

    Resin filter replacement log at 6–9 month intervals

  7. 07

    Any state authority or examiner correspondence and sign-off

  8. 08

    Your own WHS risk assessment for the fitting and servicing task

Need the technical documentation pack for an examiner or insurer? Email office@combustionenhancement.com with the model and vehicle type.

Where to next

Practical next steps.

No projected, typical or expected fuel-saving figure is published. Actual results vary materially with engine condition, duty cycle, load profile, fuel quality, installation and operating conditions. A controlled field evaluation on your own equipment, with baseline data captured before installation, is required before any commercial projection.

FAQ

Questions.

Do I need approval to fit a hydrogen enhancement unit in Australia?

Vehicle modifications in Australia are assessed under the National Code of Practice — Vehicle Standards Bulletin 14 for light vehicles up to 4.5 tonnes GVM, and Vehicle Standards Bulletin 6 for heavy vehicles above that. Whether a particular installation needs approval or engineering sign-off is a decision for your state or territory registration authority and an approved vehicle examiner, based on how the unit is mounted, powered and connected on that specific vehicle. We supply the hardware and the technical documentation; we cannot certify your vehicle and we do not act as an approving authority.

Will fitting this void my vehicle or engine warranty?

That is a question for your vehicle or engine manufacturer, and the answer varies by brand, contract and fleet agreement. Ask them in writing before fitting. Under Australian Consumer Law a manufacturer cannot void your statutory guarantees merely because an accessory is fitted, but they can decline warranty for a fault the accessory actually caused. The installation is reversible and adds nothing to the fuel system, which makes the before-and-after position easier to document — keep photographs and records either way.

What are my rights under the Australian Consumer Law?

Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and to compensation for any other reasonably foreseeable loss or damage, and to have goods repaired or replaced if they fail to be of acceptable quality and the failure does not amount to a major failure. Our written warranty is in addition to these rights, not a substitute for them.

Is there hydrogen stored on the vehicle?

No. Gas is produced on demand only while the engine is running and is consumed immediately in the intake. There is no pressurised cylinder and no accumulated volume, which is the single most important point in any hazard assessment or discussion with an examiner, insurer or safety officer.

Who can install the unit?

A suitably qualified automotive or heavy-diesel technician. We supply hardware and remote technical support only — we do not operate an installer network and we do not attend site. Where a state authority requires an approved vehicle examiner or engineering signatory to assess the modification, that person must be engaged locally.

What documentation should I keep on file?

The invoice and serial number, the installation date and odometer or hour-meter reading, photographs of the mounting, wiring and gas-line connection, your baseline consumption record, the manufacturer correspondence about warranty, and the resin filter replacement log at 6–9 month intervals. Fleets carrying out modifications at scale should hold this alongside their existing maintenance records.
Related

Continue reading.

Hydrogen combustion enhancement

What it is, how PEM gas reaches the cylinder, and what it does not do.

Engine performance improvement

Flame speed, burn completeness and load response on diesel engines.

Fuel efficiency

How to baseline and measure litres per 100 km or litres per hour.

Emissions reduction

Soot, particulate and unburnt-fuel behaviour, and how to test it.

Visible smoke reduction

Smoke opacity findings per study, with the NOx trade-off disclosed.

Remote-site fuel logistics cost

Landed cost versus pump price, and why the same percentage moves more money.

Generator-set classes

Camp, prime, standby, rental, telecom, irrigation and ship's service sets compared.

Idle & part-load duty cycles

Reefers, camp gensets and high-idle plant — where the literature reports most room.

Hydrogen with biodiesel blends

Per-study findings for hydrogen enrichment on biodiesel, NOx disclosed.

Installation guide

Nine-step fitting sequence: mounting, wiring, gas line, commissioning.

Safety & compliance

On-demand gas, no storage, alarms, shutdowns and reversibility.

Troubleshooting

Alarms, low gas output, water quality and no-start diagnostics.

Case studies & field results

Published operator data and trial methodology.

Compare PEM systems

A-450 to DH-Power side by side: displacement, output, current draw.

Does it actually work? Evidence review

The published literature, the FTC/EPA history and the ACL context.

How it works

Gas path and established physics, explained with diagrams.

PEM vs alkaline

Membrane on water versus caustic KOH: servicing, purity, cost.

Sizing combined gas

Why PEM and alkaline gas-volume benchmarks are not interchangeable for ICE sizing.

Four hydrogen technologies

Enhancement vs H2ICE vs fuel cell vs chemical generation.

Compared with Hydrogen Fuel Systems

Honest comparison with the Perth-based Gen alkaline range.

Compared with H2i Technology

Hardware, pricing and evidence transparency versus the Victorian supplier.

Compared with dynaCERT HydraGEN

PEM versus alkaline, published price versus dealer quote, Verra versus ACCU.

Compared with HYDI

The South Australian manufacturer: UniSA testing, field history and quote path.

Mining fleets

Haul trucks, dozers, drill rigs and site gensets: unit selection and dust.

Marine

Workboats, charter, fishing and ship's service gensets — no gas stored aboard.

Agriculture

Tractors, headers, pump sets and farm trucks across seasonal duty.

FAQ

Answers on fitment, water, warranty, freight and duty cycles.

Chat on WhatsApp